Corrugated roofing is an amazing choice for conventional pitched roof despite having the severe limitation about the pitch.
Pitch for metal roof 5v.
The corrugated metal roof minimum slope is 5 degrees.
3 12 minimum recommended roof pitch.
5v crimp panel product information.
This guide must by read and understood in its entirety before beginning installation.
The minimum pitch for metal roofing varies depending on the profile of the metal.
The most common slopes are.
Economy 29 and 26 gauge high strength steel.
Profile in the context of metal roofing means the shape that the sheet of metal is bent into to form the panels.
Next find the square footage of the metal roofing panels you want to use.
The pitch is measured in inches of vertical rise per foot of horizontal run and the 5v crimp profile shown above requires a minimum slope of three in twelve or 3 12 3 inches vertically per 12 inches horizontally.
In most occasions a pitch of three in twelve is preferred but this should also take into consideration the manufacturer s recommendations as well the unique condition of the corrugated metal roof.
5v crimp installation guidelines caution.
Exposed fastener panel for roof and wall applications.
Any length is available from 3 up to 45 though for handling 30 maximum is recommended.
Applications over 15 32 plywood.
Multiply the footprint square footage by the multiplier for your roof pitch to find the actual square footage of the roof.
It is the recommended slope as there is no guarantee if you opt for flatter pitch than this.
Mcelroy s 5v panels are 24 wide and incorporate a classic design that adds beauty to any home.
Use our roof pitch calculator to find the pitch of your roof.
This is intended to be a guide only and does not.
Measure the length and width in feet then multiply together to find the square footage.
Just like other metal roofs the minimum pitch for a corrugated metal roof largely depends on the profile of the roof.
5v is also commonly installed as an interior liner or accent panel.
For use by its customers.
This guide is supplied by fabral inc.
The 5v metal roof panels are designed with an enhanced u over v profile to provide maximum leak resistance.
Suitable for solid decking or open frame.
Mcelroy s 5v panel is available with fade and chalk resistant kynar 500.
The 5v crimp panel features 24 of coverage.
5v crimp roofing must be applied on a minimum roof pitch of 2 12 or greater.
Available in 26 gauge and 24 gauge.
Minimum pitch for corrugated metal roof.
5 ribs at 12 and 24 on center with 3 8 rib height.
5v crimp s design features five 1 2 high ribs two on each side and one in the middle.